SynchroPulseTM HV752 Specifications
Previous Page


COMBINATION THERAPY PACKAGE
SynchroPulse HV752 and SynchroSonic U/50
Order No. CB93

SynchroPulse HV752 Features
  • Dual channel, 4 pad stimulator
  • Dual intensity controls • Polarity control
  • Bipolar application (no dispersive pad)
  • Selectable frequency rate and pulse width
  • Selectable independent on/off surge duration
  • Surge and reciprocal modes ramped 
  • Intensity reset circuit • 30 minute timer 
  • Patient treatment stop switch
  • Combination therapy capability
  • Two Year Warranty - Parts and Labor


SynchroPulse HV752 Specifications

Input Power Requirements
 
Line Voltage 
120 Vac, 60 Hz
 (Special voltages available on request)
Current
 0.25 A
Line Leakage
 <50  µA

Electrical Stimulator
 
Waveform 
dc "needle" pulses with no parasitic spike
Output Voltage
0 to 500 peak V
Output Intensity
20  µC maximum charge
per pulse into 100 S load
Pulse Width
narrow 10 µs, medium 20 µs, wide 30 µC
Frequency Range
1-160 pulses per s 
Surge On Duration,
Reciprocal On/Off Duration 
1, 2.5, 5, 7.5, 10, 15, 20, 30 s 
Surge Off Duration
 2.5, 5, 10, 15, 20, 30, 50, 90 s

Instrument HV752
 
Overall Dimensions 
8½" W x 10¾" D x 5" H
Weight 
 8 lbs.
Shipping Weight
15 lbs.

Caution: Federal law (USA) restricts this device to sale by or on the order of a licensed practitioner

SynchroSonic® U/50 Features
  • Lightweight standard transducer 
  • Optional QuickConnectTM transducer 
  • Optional small transducer with QuickConnect cable
  • Cable fault alarm system 
  • Transducer protection switch 
  • Adjustable interrupted output mode
  •  0 to 20 watt output    •  30 minute timer
  • Two Year Warranty - Generator - Parts and Labor
  • One Year Warranty - Transducer - Parts and Labor
  • UL Listed      •  CSA Approved


SynchroSonic U/50 Specifications

Input Power Requirements
 
Line Voltage 
120 Vac, 60 Hz
Current
1.0 A
Line Leakage
 <50  µA

Ultrasonic Generator
(Complies with FDA Regulation 21 CFR 1050.10 and FCC Regulations)
 
Frequency
1.0 MHz ± 5%
Waveform
amplitude modulated at 120 Hz ± 1%
Pulse Duration 
8 ms ± 1%
Output Mode
adjustable interrupted & non-interrupted
Output Power
0 to 20 W total ± 20%
0 to 5 W/cm² ± 20%
Temporal Peak/Temporal Average Intensity 
2.8:1 ± 20%
 Applicator (Transducer)
 
Crystal Material 
barium-titanate
Applicator Beam Type
collimating
Frequency
 1.0 MHz ± 5%
ERA (Effective Radiating Area)
4 cm² ± 20% 
BNR (Beam Nonuniformity Ratio)
5.5:1 maximum
Small Faceplate Size
1.5" diameter
Standard Faceplate Size
2.25" diameter



Previous Page

Return to HV752

Federal law (USA) restricts Amrex electrotherapy instruments to sale by
or on the order of a licensed practitioner


\\ Welcome || Dealers || Products || Instructional Videos || Accessories //
\\
ATS || L.A. Door to Door Factory Service || Patient Leads || Trade-In Program //
\\
News || Amrex 1-3.3 MHz Ultrasound Output || Contact Us //
\\
User's Guides || History //


 


a division of Amrex-Zetron, Inc.
641 East Walnut Street, Carson, California 90746
Telephone: (800) 221-9069 or (310) 527-6868