Expand Your Healing Touch
with Amrex Electrotherapy Equipment
CB95 Package
Quality, Effective Combination Therapy for Application of
Therapeutic Stimulation and Therapeutic Ultrasound

 

AMREX
CB95
Z-Stim IF250 Interferential / Russian Stimulator and SynchroSonic U/50 Ultrasound
with Mobile Utility Cart and Mounting Bracket

|| Z-Stim IF250 Specification ||

|| U/50 Specification Sheet ||

Interferential Stimulator Z-Stim IF250
The Z-Stim IF250 is a TRUE Interferential Stimulator with two channel, four pad output.  Each channel generates separate frequencies which interact at the treatment site producing TRUE interferential therapy.
The Amrex Z-Stim IF250 microprocessor controlled stimulator provides three widely used modalities: Quad-Polar interferential, Bi-Polar interferential and Russian stimulation.
Interferential current is designed for therapeutic stimulation of nerves and muscle in the treatment of acute pain, edema reduction and muscle rehabilitation.
The Quad-Polar Interferential modality provides twelve selectable beat frequencies - six constant and six sweep. The Quad-Polar modality features a dynamic output cycle which increases the interferential stimulation target field. The Bi-Polar Interferential modality provides premodulated, four pad, two channel interferential treatment. The Bi-Polar modality features twelve selectable modulation frequencies - six constant and six sweep.
The Russian (2500 Hz) modality provides four pad, two channel Russian stimulation featuring a continuous, exercise or rehab treatment mode.
The IF250 features a treatment stop switch designed to instill patient confidence. The treatment stop switch allows the patient to discontinue stimulator output at the press of a button.

SynchroSonic U/50
The versatile SynchroSonic U/50 provides therapeutic ultrasound which may be applied separately or which may be combined with electrical stimulation simultaneously through the ultrasound transducer using an external electrical stimulator.
The cable fault alarm system is an added feature of the U/50.  This system will detect improper transducer cable connection and/or transducer cable damage.  If such detection is made, an audible signal will alert the practitioner.

IF250 Features

  • Microprocessor controlled
  • Solid state circuitry
  • 12 pre-program beat frequency settings
              6 constant settings
              6 sweep ranges
  • 4000 Hz treatment frequency
  • Frequency, Time and Milliamp digital displays
  • Quad-Polar, Bi-Polar, and Russian modalities
  • Dynamic mode (Quad-Polar only)
  • Time adjustment 1 to 99 minutes
  • Push button controls
  • Patient treatment stop switch
  • Intensity reset circuit
  • Tilt-up bar
     
  • City of Los Angeles Electrical Testing Laboratory Approved Under UL544 Guideline

U/50 Features

  • Lightweight standard transducer 
  • Optional QuickConnectTM transducer
  • Optional small transducer with QuickConnect cable
  • Cable fault alarm system - U/50
  • Transducer protection switch - U/50
  • Adjustable interrupted output mode - U/50
  • 0 to 20 watt output - U/50
  • 0 to 12 watt output - U/20 
  • 30 minute timer
  • UL Listed
  • CSA Approved

Mobile Utility Cart Features

  • Durable, high-impact polyethylene construction
  • Lightweight, mobile, and easy to maneuver
  • Three large shelves
  • Tool-free assembly

Mounting Bracket Features

  • Anodized aluminum construction
  • Wall mountable

Federal law (USA) restricts Amrex electrotherapy instruments to sale by
or on the order of a licensed practitioner


\\ Welcome || Dealers || Products || Instructional Videos || Accessories //
\\
ATS || L.A. Door to Door Factory Service || Patient Leads || Trade-In Program //
\\
News || Amrex 1-3.3 MHz Ultrasound Output || Contact Us //
\\
User's Guides || History //


 


a division of Amrex-Zetron, Inc.
641 East Walnut Street, Carson, California 90746
Telephone: (800) 221-9069 or (310) 527-6868
Fax: (310) 366-7343
Web Site: http://www.amrex-zetron.com

 

Copyright © 1998 Amrex-Zetron Corporation. All rights reserved.
Last modified on
January 24, 2007

 

Web Site Creator:
Produced and Maintained by Paul Elliott: Designer/Graphics
E-Mail: pkelliot@gte.net

Comments, suggestions welcome!